Haas CNC Alarm 693 (Mill) W AXIS DRIVE FAULT

Haas CNC Alarm 693 (Mill) W AXIS DRIVE FAULT
Alarm Description, Cause & Remedy
Current in W servo motor beyond limit. Possibly caused by a stalled or overloaded motor. The servos are turned off. This can be caused by running the axis into a mechanical stop, a short in the motor or a short of one motor lead to ground.