Fanuc Robot Alarm TPIF-128 Verify logic of pasted line(s)

Fanuc Robot Alarm TPIF-128 Verify logic of pasted line(s)
Cause: The reverse motion copy function does not support the following motion option instruction. 1. Application command 2. Skip, Quick Skip 3. Incremental 4. Continuous turn 5. Time before
Remedy: Check the above motion option instruction. And modify the copied statement correctly.