Fanuc alarm: 383 – n AXIS : PULSE MISS (EXT)

CNC Machine Alarm Error & Message: 383 – n AXIS : PULSE MISS (EXT)
Fanuc Alarm Description:
A count error occurred in the separate detector.

Additional Suggestions & Fanuc alarm: 383 – n AXIS : PULSE MISS (EXT) Clarification:
EXT= External feedback coder used possibly a scale or separate encoder. If a scale-dirt or contamination may be present on sensor or glass. Cleaning can sometimes fix the problem.

Troubleshooting Recommendations for (Fanuc alarm: 383 – n AXIS : PULSE MISS (EXT)) Error Message:

Fanuc CNC Control Models Applicable:16/18/21, 16i/18i/21i, 160i/180i/210i, ,