Fanuc alarm: 360 – n AXIS : ABNORMAL CHECKSUM (INT)

CNC Machine Alarm Error & Message: 360 – n AXIS : ABNORMAL CHECKSUM (INT)
Fanuc Alarm Description:
A checksum error occurred in the built-in pulse coder.

Additional Suggestions & Fanuc alarm: 360 – n AXIS : ABNORMAL CHECKSUM (INT) Clarification:
Most likely the pulse coder- replace it

Troubleshooting Recommendations for (Fanuc alarm: 360 – n AXIS : ABNORMAL CHECKSUM (INT)) Error Message:

Fanuc CNC Control Models Applicable:16/18/21, 16i/18i/21i, 160i/180i/210i, ,


Fanuc alarm: 360 – n AXIS : ABNORMAL CHECKSUM (INT)